Designed for process applications, Emco measures liquids, gas or steam. Accuracy is ±0.7 percent of rate for liquids and ±1 percent for gas and steam, with ±0.15 percent of rate repeatability. Its output signals are scalable 4 to20 mA current and scalable frequency/pulse 0 to10 kHz over the HART 268 communications protocol. A local LCD screen displays flow rate and totalized flow. It is handles temperatures from -40 to 750°F (-40 to 400°C) and has a pressure rating to ANSI class 600.
Spirax Sarco Inc. • (803) 714-2072 www.spiraxsarco.com/us